Tower Internal Manways

Contract maintenance workers often will not replace the tray manways unless the tray manway is adjacent to a tower external manway. They reason that once the tray manways that are visible from the tower manway are closed, there is no … Continue reading

30. April 2011 by Jack
Categories: Tower Pressure | Tags: | Leave a comment

Tower Final Inspection

At a Gulf Coast refinery, the reboiler thermosyphon circulation could not be reestablished after a turnaround. The tower was reopened and a lessthan-alive contract employee was found stuck in the reboiler draw-off nozzle. At the Good Hope Refinery (when I … Continue reading

30. April 2011 by Jack
Categories: Tower Pressure | Tags: | Leave a comment

Shear Clips

If a tower has a history of tray deck damage due to pressure surge or high liquid level, the mechanical integrity of the trays should be upgraded. This is done by the use of shear clips, as shown in Fig. … Continue reading

30. April 2011 by Jack
Categories: Tower Pressure | Leave a comment

Seal Pans Downcomer

The downcomer from the bottom tray is submerged in a seal pan (see Fig. 8.3), to preserve its downcomer seal. I always set the horizontal dimension between the over-flow lip of the seal pan, (dimension y) the downcomer at four … Continue reading

30. April 2011 by Jack
Categories: Tower Pressure | Tags: , | Leave a comment